Skip to main content

The BIOFIRE® SPOTFIRE® Respiratory Solution

Multiplex PCR Testing Built for the Point of Care

An evolving world deserves evolved diagnostics. As the leader in syndromic PCR testing, bioMérieux has evolved our point-of-care respiratory testing solution by developing new products that put clinicians and patients front and center. bioMérieux is pleased to announce a revolutionary portfolio of versatile, lab-grade respiratory PCR tests that give clinicians options as they care for a variety of patients.

Product Overview

The BIOFIRE® SPOTFIRE® System

The SPOTFIRE System is the latest advancement in molecular infectious disease diagnostics. It is designed to run the SPOTFIRE Respiratory Panels.

  • Requires minimal benchtop space and can be scaled vertically, up to four modules, enabling customizable throughput
  • Easy to use with an intuitive system interface and streamlined workflow
  • Can be used by any healthcare professional in any healthcare setting
  • Seamlessly connects with point-of-care data management systems and other compatible systems and software
female-tech-using-torch-instrument

1. Calculation based on running the BIOFIRE® SPOTFIRE® R PANEL (~15 minutes) in an 8 hour shift.

BIOFIRE® SPOTFIRE® Respiratory/Sore Throat (R/ST) Panel*

1 PCR Test. Up to 15 Targets. ~15 Minutes.

The SPOTFIRE R/ST Panel enables testing for both respiratory or sore throat pathogens on the same panel, providing a flexible respiratory solution to meet the unique needs of your care setting.  FDA CLEARED | CLIA WAIVED

*Product not yet available for sale.

female-tech-using-torch-instrument
Sample Type: Nasopharyngeal or throat swab in transport media 
Hands-on time: 1-2 minutes
Overall Respiratory Performance (NPS specimens): PPA: 98.5% NPA: 99.1%
Overall Sore Throat Performance (TS specimens): PPA: 95.9% NPA: 99.0%
SPOTFIRE R/ST PANEL MENU
RESPIRATORYSORE THROAT
VIRUSES:VIRUSES:
  • Adenovirus
  • Coronavirus SARS-CoV-2
  • Coronavirus (seasonal)
  • Human metapneumovirus
  • Human rhinovirus/enterovirus
  • Influenza A virus
    • Influenza A virus A/H1-2009
    • Influenza A virus A/H3
  • Influenza B virus
  • Parainfluenza virus
  • Respiratory syncytial virus
  • Adenovirus
  • Coronavirus (seasonal)
  • Human metapneumovirus
  • Human rhinovirus/enterovirus
  • Influenza A virus
    • Influenza A virus A/H1-2009
    • Influenza A virus A/H3
  • Influenza B virus
  • Parainfluenza virus
  • Respiratory syncytial virus
BACTERIA:BACTERIA:
  • Bordetella parapertussis
  • Bordetella pertussis
  • Chlamydia pneumoniae
  • Mycoplasma pneumoniae
  • Chlamydia pneumoniae
  • Mycoplasma pneumoniae
  • Streptococcus dysgalactiae (group C/G strep)
  • Streptococcus pyogenes (group A strep)

BIOFIRE® SPOTFIRE® Respiratory/Sore Throat (R/ST) Panel Mini**

1 PCR Test. 5 Targets. ~15 Minutes.

The SPOTFIRE R/ST Panel Mini tests for the 5 most probable viruses or bacteria that cause respiratory and sore throat symptoms, including influenza, rhinovirus, respiratory syncytial virus SARS-CoV-2, and streptococcal pharyngitis.

**Under FDA review. Intending to seek CLIA waiver. Subject to change. Product not available for sale.

female-tech-using-torch-instrument

Panel Specifications

Sample Type:
 Nasopharyngeal or throat swab in transport media 
Hands-on time: 1-2 minutes
Overall Respiratory Performance (NPS specimens): N/A
Overall Sore Throat Performance (TS specimens): N/A
SPOTFIRE R/ST PANEL MINI MENU
RESPIRATORYSORE THROAT
VIRUSES:VIRUSES:
 
  • Coronavirus SARS-CoV-2
  • Human rhinovirus
  • Influenza A virus
  • Influenza B virus
  • Respiratory syncytial virus
  • Human rhinovirus
  • Influenza A virus
  • Influenza B virus
  • Respiratory syncytial virus
 BACTERIA:
 
  • Streptococcus pyogenes (group A strep)

BIOFIRE® SPOTFIRE® Respiratory (R) Panel

1 PCR Test. 15 Targets. ~15 Minutes.

The SPOTFIRE R Panel brings diagnostic power to clinicians via a lab-grade, PCR-based expanded syndromic approach. In other words, the SPOTFIRE R Panel combines symptom-driven testing for a broad grouping of probable respiratory pathogens into one rapid test that aids in the diagnosis of patients experiencing signs or symptoms of respiratory tract infections, maximizing the change of getting an actionable answer in a clinically relevant timeframe.

FDA CLEARED | CLIA WAIVED

female-tech-using-torch-instrument

Panel Specifications

Sample Type:
Nasopharyngeal swab in 1-3 mL of viral transport media
Hands-on time: 1-2 minutes
Overall Performance:PPA: 98.5%, NPA: 99.1%
SARS-CoV-2 Performance:2PPA: 97.3%, NPA: 99.4%
SPOTFIRE R PANEL MENU
VIRUSES:BACTERIA:
 
  • Adenovirus
  • Coronavirus SARS-CoV-2
  • Coronavirus (seasonal)
  • Human metapneumovirus
  • Human rhinovirus/enterovirus
  • Influenza A virus
    • Influenza A virus A/H1-2009
    • Influenza A virus A/H3
  • Influenza B virus
  • Parainfluenza virus
  • Respiratory syncytial virus
  • Bordetella parapertussis
  • Bordetella pertussis
  • Chlamydia pneumoniae
  • Mycoplasma pneumoniae

 

BIOFIRE® SPOTFIRE® Respiratory (R) Panel Mini

1 PCR Test. 5 Targets. ~15 Minutes.

The SPOTFIRE R Panel Mini brings the power of targeted syndromic testing via lab-quality PCR results to the front line. It tests for the 5 most probable viruses that cause respiratory tract infections, including influenza, rhinovirus, respiratory syncytial virus, and SARS-CoV-2. This panel runs on the easy-to-use SPOTFIRE System, which provides results in about 15 min.

FDA CLEARED | CLIA WAIVED

female-tech-using-torch-instrument

Panel Specifications

Sample Type:
Nasopharyngeal swab in 1-3 mL of viral transport media
Hands-on time: 1-2 minutes
Overall Performance:PPA: 98.7% NPA: 98.4%
SARS-CoV-2 Performance:2PPA: 97.3%, NPA: 99.4%
SPOTFIRE R PANEL MINI MENU
VIRUSES:BACTERIA:
 
  • Coronavirus SARS-CoV-2
  • Human rhinovirus
  • Influenza A virus
  • Influenza B virus
  • Respiratory syncytial virus
  • Human rhinovirus
  • Influenza A virus
  • Influenza B virus
  • Respiratory syncytial virus

 


Rethink the Power of Diagnostics with the SPOTFIRE Respiratory Solution to Potentially:

Inform Clinical Decisions

  • High sensitivity, specificity, and reliability provides results clinicians can trust
  • Contrary to tests that only detect the flu, SARS-COV-2, and/or RSV, a syndromic panel provides a fuller picture that may help inform patient management decisions

Optimize Operations

  • The simplified workflow and quick turnaround time enable rapid and accurate answers during the patient visit, while reducing the need for callbacks or expensive and slow send-out testing
  • This easy-to-use solution enables users of all skill levels to prepare and run samples

Optimize Antimicrobial Stewardship

  • Receiving comprehensive results in a clinically actionable timeframe may inform diagnoses while optimizing care and antimicrobial stewardship

Improve Patient Satisfaction

  • Using the right test, the first time to detect multiple pathogens may result in reduced follow-up appointments, swabbing, and testing, which could improve patient comfort, experience, and convenience
lab-techs-using-torch-instrument

Product availability varies by country. Consult your bioMérieux representative. 

Reference:

  1. Calculation based on running the BIOFIRE® SPOTFIRE® R PANEL (~15 minutes) in an 8 hour shift.
  2.  Overall performance and SARS-CoV-2 performance based on the prospective clinical study for the BIOFIRE SPOTFIRE Respiratory Panel.

 

Technical Details

SPOTFIRE Respiratory Panel:

  • Sample Type: Nasopharyngeal swab in 1-3 mL of viral transport media
  • Hands-on time: 1-2 minutes
  • Overall Peformance:1 PPA: 98.5%, NPA: 99.1%
  • SARS-CoV-2 Performance:1 PPA: 97.3%, NPA: 99.4%

SPOTFIRE Respiratory Panel Mini:

  • Sample Type: Nasopharyngeal swab in 1-3 mL of viral transport media
  • Hands-on time: 1-2 minutes
  • Overall Performance:1 PPA: 98.7%, NPA: 98.4% 
  • SARS-CoV-2 Performance:1 PPA: 97.3%, NPA: 99.4%

SPOTFIRE Respiratory Panel Menu

VIRUSES:

  • Adenovirus
  • Coronavirus SARS-CoV-2
  • Coronavirus (seasonal)
  • Human metapneumovirus
  • Human rhinovirus/enterovirus
  • Influenza A virus
    • Influenza A virus A/H1-2009
    • Influenza A virus A/H3
  • Influenza B virus
  • Parainfluenza virus
  • Respiratory syncytial virus

BACTERIA:

  • Bordetella parapertussis
  • Bordetella pertussis
  • Chlamydia pneumoniae
  • Mycoplasma pneumoniae

SPOTFIRE Respiratory Panel Mini Menu

VIRUSES:

  • Coronavirus SARS-CoV-2
  • Human rhinovirus
  • Influenza A virus
  • Influenza B virus
  • Respiratory syncytial virus

Product Information

PRODUCT NAMEPART NUMBERQUANTITY 
BIOFIRE SPOTFIRE Respiratory Panel Kit 42446130-Pack
BIOFIRE SPOTFIRE Respiratory Panel Mini Kit 42458930-Pack
SPOTFIRE RSP Pos & Neg ControlsM4252 boxes (1 x M42638, 1 x M42738) 
SPOTFIRE RSP Positive ControlsM426381 box (6 tubes)
SPOTFIRE RSP Negative ControlsM427381 box (6 tubes)
NATtrolTM Respiratory Verification PanelNATRSP-BIO1 Panel
NATtrol™ Respiratory Verification Panel MiniNATRMP-BIO1 Panel
BIOFIRE SPOTFIRE Respiratory Panel, Verification Kit 4245951 x NATRSP-BIO, 5 x M425, 3 x 424461
BIOFIRE SPOTFIRE Respiratory Panel Mini, Verification Kit 4245961 x NATRMP-BIO, 5 x M425, 3 x 424461 
BIOFIRE SPOTFIRE Control StationFAST-ASY-00011
BIOFIRE SPOTFIRE ModuleFAST-ASY-00021

Service & Support

With the urgent nature of patient and community care, we take pride in addressing all concerns quickly and accurately. bioMérieux is dedicated to providing world class customer support 24 hours a day, 7 days a week, 365 days a year.

For assistance please contact our customer technical support team at:

To order, contact your regional sales representative or use the following contact information: